The Japan Times - France's City of Light switches to climate-resilient power cables

EUR -
AED 4.282286
AFN 72.889506
ALL 95.207603
AMD 430.01375
ANG 2.087753
AOA 1070.42764
ARS 1622.784305
AUD 1.615801
AWG 2.101792
AZN 1.980037
BAM 1.948086
BBD 2.348989
BDT 143.162498
BGN 1.947198
BHD 0.439945
BIF 3468.977203
BMD 1.166043
BND 1.484988
BOB 8.058985
BRL 5.837324
BSD 1.166277
BTN 111.748109
BWP 16.426743
BYN 3.258314
BYR 22854.438042
BZD 2.345552
CAD 1.600621
CDF 2617.765364
CHF 0.914545
CLF 0.02651
CLP 1043.367038
CNY 7.911775
CNH 7.916136
COP 4418.987218
CRC 529.980953
CUC 1.166043
CUP 30.900133
CVE 110.420738
CZK 24.310883
DJF 207.229054
DKK 7.473652
DOP 69.611585
DZD 154.439062
EGP 61.655687
ERN 17.490641
ETB 183.593618
FJD 2.556084
FKP 0.862511
GBP 0.870795
GEL 3.124803
GGP 0.862511
GHS 13.304314
GIP 0.862511
GMD 84.53284
GNF 10237.855419
GTQ 8.897767
GYD 243.990718
HKD 9.133322
HNL 31.040319
HRK 7.5352
HTG 152.719375
HUF 357.85873
IDR 20501.247154
ILS 3.384559
IMP 0.862511
INR 111.602244
IQD 1527.516012
IRR 1533346.225611
ISK 143.609809
JEP 0.862511
JMD 184.399822
JOD 0.82669
JPY 184.674396
KES 150.710561
KGS 101.97073
KHR 4678.163038
KMF 492.06927
KPW 1049.40427
KRW 1743.787798
KWD 0.359712
KYD 0.971947
KZT 552.061604
LAK 25600.468408
LBP 105018.290233
LKR 379.337915
LRD 213.677252
LSL 19.227736
LTL 3.443021
LVL 0.705327
LYD 7.380747
MAD 10.737796
MDL 20.047359
MGA 4871.140463
MKD 61.623214
MMK 2448.532445
MNT 4174.584911
MOP 9.409221
MRU 46.630148
MUR 54.687743
MVR 17.953612
MWK 2030.079949
MXN 20.097411
MYR 4.5843
MZN 74.521703
NAD 19.22769
NGN 1596.510503
NIO 42.811215
NOK 10.814812
NPR 178.792592
NZD 1.975224
OMR 0.448341
PAB 1.166257
PEN 4.019331
PGK 5.084821
PHP 71.905202
PKR 324.858355
PLN 4.243469
PYG 7106.858587
QAR 4.250809
RON 5.201602
RSD 117.404153
RUB 85.416661
RWF 1703.588468
SAR 4.323481
SBD 9.347158
SCR 15.925798
SDG 700.210747
SEK 10.964079
SGD 1.488553
SHP 0.870569
SLE 28.742478
SLL 24451.336053
SOS 666.396592
SRD 43.384983
STD 24134.730844
STN 24.778409
SVC 10.204331
SYP 128.881228
SZL 19.227966
THB 37.837714
TJS 10.898504
TMT 4.08115
TND 3.367544
TOP 2.807551
TRY 53.109051
TTD 7.918441
TWD 36.822696
TZS 3025.881057
UAH 51.26883
UGX 4361.616853
USD 1.166043
UYU 46.444895
UZS 14044.985317
VES 594.855331
VND 30719.39644
VUV 137.683599
WST 3.158251
XAF 653.355863
XAG 0.013988
XAU 0.000251
XCD 3.151288
XCG 2.101868
XDR 0.810364
XOF 650.065331
XPF 119.331742
YER 278.276306
ZAR 19.248742
ZMK 10495.787518
ZMW 21.954032
ZWL 375.465292
  • RBGPF

    0.8900

    61.68

    +1.44%

  • JRI

    0.0100

    13.14

    +0.08%

  • BCE

    -0.2000

    24.19

    -0.83%

  • BP

    -0.0200

    44.12

    -0.05%

  • BTI

    1.3500

    66.7

    +2.02%

  • CMSC

    0.0898

    23.14

    +0.39%

  • RELX

    -0.1600

    31.46

    -0.51%

  • RYCEF

    -0.1300

    15.9

    -0.82%

  • BCC

    2.4200

    69.4

    +3.49%

  • GSK

    -0.0300

    50.96

    -0.06%

  • RIO

    -2.4500

    109.59

    -2.24%

  • VOD

    -0.0300

    15.48

    -0.19%

  • NGG

    0.4500

    87.43

    +0.51%

  • CMSD

    0.0400

    23.6

    +0.17%

  • AZN

    -2.7600

    184.96

    -1.49%

France's City of Light switches to climate-resilient power cables
France's City of Light switches to climate-resilient power cables / Photo: STRINGER - AFP

France's City of Light switches to climate-resilient power cables

To maintain the glow of the City of Light, Paris is modernising its underground electric cables, vulnerable to damage during heatwaves and dating back 60 years.

Text size:

With power cables melting from Portland to Sicily, the world's 80 million kilometres (50 million miles) of power lines are largely unprepared to resist extreme temperatures, scientists have warned.

The French capital over the next few months will be replacing its obsolete paper-insulated lead-covered cables (PILC), which are made of oil-impregnated paper encased in a lead sheath.

"We're anticipating the renewal of these cables, which are starting to be affected by heat, to have a very resilient network in Paris," said Olivier Lagnel, deputy regional director for utility firm Enedis.

Nearby, workers in orange vests worked in a trench close to the Montparnasse train station to replace the medium voltage PILC, which were installed in 1965, with modern, plastic cables.

State-owned Enedis says Paris is not alone: its counterparts in Chicago, London, Shanghai, Hong Kong, Osaka, Tokyo, Singapore and Sydney also plan to update their cables.

- 'Climate emergency' -

Trouble has mounted in recent years.

Paper-insulated during a 2003 heatwave in France showed weaknesses with "an incident rate multiplied by eight across the medium-voltage underground network", according to a March 2024 report by France's Court of Audit.

Overhead tramway cables melted in Portland in 2021 during record-high temperatures in the northwest US state of Oregon.

A searing heatwave in July 2023 left hundreds of thousands of Sicilians without electricity and water for days.

Heat damage to underground cables was to blame, said supplier e-distribuzione, the distribution arm of energy giant Enel.

"We find ourselves operating in conditions of exceptional climatic emergency," where the temperature of the asphalt on roads reached 50 degrees Celsius (122 degrees Fahrenheit), it said in a statement at the time.

A 2021 study led by Alessandro Bosisio, an assistant professor at the University of Pavia in Italy, found that "an abnormal increase of faults in underground Medium Voltage cable joints has been recorded, especially during summer" worldwide in recent years.

Climate scientists say the period being lived through right now is likely the warmest the earth has seen for the last 100,000 years, back at the start of the last Ice Age.

- Avoid cuts -

PILC cables, which were the international standard from the late 19th century until the 1970s, were long considered highly reliable.

They were wrapped in layers of oily paper intended to isolate the centre of the cable, which heats up as electrons pass through.

The cables were conceived to resist temperatures up to 90C (194F). But when heat is trapped for days under the asphalt, they can reach 120-130C (248-266F) -- ageing faster and eventually risking failure.

Paris's 9,200 kilometres of low- and medium-voltage power cables are entirely buried underground -- to save space and protect them from the wind, Lagnel said.

Enedis plans to phase out the obsolete cables in French cities by 2050.

"The main problem is that the insulator can dry up, and in that case the cable can be sensitive," said Lagnel.

"The idea is to avoid cuts as much as possible" and to "desensitise the network... as heatwaves come back more and more often, stronger and stronger."

K.Tanaka--JT